½ð²Ê»ã

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹â×êÑл㱨¡· £¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¢¼´ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
½ð²Ê»ã - Ê×Ò³
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
½ð²Ê»ã - Ê×Ò³

CXL¼¼ÊõÈôºÎ½â¾öÊý¾ÝÖÐÐÄÄÚ´æÎÊÌ⣨ÉÏ£©

½ð²Ê»ã - Ê×Ò³ °ä²¼¹¦·ò£º2023-07-20
½ð²Ê»ã - Ê×Ò³

CXL£¨Compute Express Link£© £¬ÊÇÒ»ÖÖȫеÄÉ豸»¥Áª¼¼Êõ³ß¶È £¬ÒѳÉΪҵ½çÍ»ÆÆÄÚ´æÆ¿¾±µÄ´æ´¢Ð¼¼Êõ¡£²»½öÓÃÓÚÄÚ´æÈÝÁ¿/´ø¿íÀ©´ó £¬»¹ÓÃÓÚÒì¹¹»¥Áª £¬Êý¾ÝÖÐÐÄ×ÊÔ´³Ø½âñî¡£ÔÚÊý¾ÝÖÐÐÄ £¬CXL¼¼ÊõÄܹ»½«·ÖÆçµÄÍÆËãºÍ´æ´¢×ÊÔ´½øÐл¥Áª £¬Óøü¸ßµÄϵͳ»úÄܺÍЧÄÜÀ´½â¾öÊý¾ÝÖÐÐÄÄÚ´æÎÊÌâ¡£

CXL¼¼ÊõµÄ³öÏÖ

ÔÆÍÆËã¡¢´óÊý¾Ý·ÖÎö¡¢ÈËΪÖÇÄÜ¡¢»úе½ø½¨µÅצÓõļ±¾ç·¢Õ¹´øÀ´Êý¾ÝÖÐÐÄ´æ´¢ºÍ´¦ÖÃÊý¾ÝÐèÒªµÄ±¬Õ¨ÐÔÔö³¤¡£´«Í³DDRÄÚ´æ½Ó¿Ú´æÔÚ×Ü´ø¿í¡¢Ã¿Ö÷Ìâ¾ùÔÈ´ø¿íºÍÈÝÁ¿¿ÉÀ©´óÐÔÊÜÏÞµÈÎÊÌâ¡£ÓÈÆäÔÚÊý¾ÝÖÐÐÄ £¬ÊÜÏÞÓÚ´óÁ¿ÄÚ´æÎÊÌâ £¬ÐµÄÄÚ´æ½Ó¿Ú¼¼ÊõCXL³öÏÖ¡£

ÔÚÊý¾ÝÖÐÐÄ £¬CPUÄÚ´æÊǽôñîºÏ¹ØÏµ £¬Ã¿´úCPU¶¼Ñ¡È¡ÐµÄÄÚ´æ¼¼ÊõʵÏÖ¸ü¸ßµÄÈÝÁ¿ºÍ´ø¿í¡£×Ô2012ÄêÒÔÀ´ £¬Ö÷ÌâÊýÁ¿Ñ¸ËÙÔö³¤ £¬µ«Ã¿¸öÄں˵ÄÄÚ´æ´ø¿íºÍÈÝÁ¿²¢Î´ÏàÓ¦Ôö³¤ £¬·´¶ø½µÂä¡£ÕâÖÖÇ÷Ïò½«ÔÚ½«À´³ÖÐø £¬ÄÚ´æÈÝÁ¿Ôö³¤ËÙ¶ÈÒ²¿ìÓÚÄÚ´æ´ø¿í £¬Õâ¶Ôϵͳ»úÄÜÓ°Ïì¾Þ´ó¡£

´Ë±í £¬Ö±Á¬DRAMºÍSSDÔÚÑÓ³¤ºÍ³É±¾·½ÃæµÄ¾Þ´ó²î¾à £¬Ê¹µÃ°º¹óµÄÄÚ´æ×ÊÔ´ÍùÍùÀûÓÃÂʺܵÍ £¬ÃýÎóµÄÍÆËãºÍÄÚ´æ±ÈÀýºÜÈÝÒ×Ôì³ÉÄÚ´æÏÐÖã¨Stranded£©×â²»³öÈ¥µÄ¾°Ïó¡£Êý¾ÝÖÐÐÄÒµÎñ×÷ΪȫÇò±¾Ç®×îÃܼ¯µÄÐÐÒµÖ®Ò» £¬µÍÀûÓÃÂÊÊÇÒ»¸öºÜ´óµÄÖ°ÊØ¡£Î¢Èí°µÊ¾ £¬50%µÄ·þÎñÆ÷×ܳÉÕý±¾×ÔDRAM¡£Ö»¹ÜDRAM³É±¾ºÜ¸ß £¬µ«25%µÄDRAMÄڴ滹ÊÇÀË·ÑÁË¡£ÏÂͼÀ´×ÔMetaÄÚ²¿µÄͳ¼ÆÊý¾ÝÒ²ÏÔʾÀàËÆ¾°Ïó¡£ÄÚ´æ³É±¾Õ¼ÏµÍ³×ܳɱ¾µÄ±ÈÀýÏÖʵÉÏÔÚ²»ÐÝÉÏÉý £¬ÏµÍ³µÄÖØÒª³É±¾ÒѾ­Ôì³ÉÊÇÄÚ´æ¶ø²»ÊÇCPU×ÔÉí £¬Ê¹ÓÃCXLÄÚ´æ×ÊÔ´³ØÄܹ»ÓÐЧ¸ÄÉÆÕâÒ»ÎÊÌâ £¬Í¨¹ý¸øÏµÍ³¶¯Ì¬·ÖÅäÄÚ´æ×ÊÔ´Äܹ»ÓÅ»¯ÍÆËãºÍÄÚ´æ±ÈÀý¹ØÏµÓÅ»¯TCO¡£

½ð²Ê»ã - Ê×Ò³

·ÖÆçÄÚ´æ¼¼ÊõµÄÑÓ³¤¸Å¿ö

½ð²Ê»ã - Ê×Ò³

ÄÚ´æ´ø¿í/ÈÝÁ¿Ë湦·òÍÆÒÆÔö³¤

½ð²Ê»ã - Ê×Ò³

·ÖÆç´úÄÚ´æÔÚ»ú¼ÜTCO/¹¦ºÄÕ¼±È

½ð²Ê»ã - Ê×Ò³

 Microsoft AzureÄÚ´æÏÐÖÃ

»ùÓÚ´«Í³ÄÚ´æÎÊÌâ £¬Òµ½çÒ»ÏòÔÚ×·ÇóѡȡеÄÄÚ´æ½Ó¿Ú¼¼ÊõºÍϵͳ¼Ü¹¹¡£

ÔÚÄÚ´æ½Ó¿Ú¼¼Êõ·½Ãæ £¬PCI-Express(peripheral  component interconnect express)³ÉΪÊ×Ñ¡¡£PCIeÊÇ´®ÐÐ×ÜÏß £¬Ê¹ÓÃPCIe´Ó»úÄܺÍÈí¼þµÄ½Ç¶ÈÀ´¿´·ÖÆçÉ豸֮¼äͨѶµÄ¿ªÏúÏà¶Ô½Ï¸ß £¬µ«ºÃÐÂÎÅÊÇ £¬PCIe½«ÒÀÕÕ´òËãÔÚ2023Äêµ×ʵÏÖ7.0°æµÄºË×¼ £¬Ìṩ¸ß´ï256GB/s µÄËÙ¶È£»Õâ¾àÀë16 GT/sËٶȵÄ4.0°æPCIeÎÊÊÀ»¹²»µ½Á½Äê¡£¼Ó¿ìPCIe·¢Õ¹À¶Í¼µÄÖØÒªÍÆÊÖÊÇÔÆ¶ËÔËËãÐèÒª£»¶øPCIeÒÔÍùÊÇÿ3~4Äê £¬ÉõÖÁÊÇ7Äê»á½«Êý¾Ý´«ÊäËÙ¶ÈÌáÉýÒ»±¶¡£

½ð²Ê»ã - Ê×Ò³

PCIe vs DDR ´ø¿í¶Ô±È

ϵͳ¼Ü¹¹ÔòÊÇÀú¾­¼¸´ú½ø»¯¸üµü¡£×î³õΪʵÏÖ¶à¸ö·þÎñÆ÷¹²Ïí×ÊÔ´³ØµÄ³¢ÊÔ £¬Í¨³£Ê¹ÓÃRDMA¼¼ÊõÔÚͨÓÃÒÔÌ«Íø»òInfiniBandÉÏÃæÊµÏÖ £¬ÕâЩͨѶ²½Öèͨ³£Ê±ÑÓ¸ü¸ß£¨±¾µØÄڴ漸ʮÄÉÃëvsRDMA¼¸¸ö΢Ã룩ºÍ¸üµÍµÄ´ø¿í £¬²¢ÇÒÒ²ÎÞ·¨ÌṩÄÚ´æÒ»ÖÂÐԵȹؼüÖ°ÄÜ¡£

½ð²Ê»ã - Ê×Ò³

ÔÚ40GbpsÁ´Â·´ø¿íÍøÂç¿ÉʵÏÖµÄÍù·µÑÓ³¤£¨×ܼƣ©
ÒÔ¼°µ¼ÖÂÍù·µÑÓ³¤Ôö³¤µÄ×é¼þ£¨Ê¹ÓÃ100Gbps¿É½«Êý¾Ý´«ËÍÏ÷¼õ0.5us£©

2010Äê £¬CCIX³ÉΪDZÔÚµÄÐÐÒµ³ß¶È¡£ËüµÄÇý¶¯³É·ÖÊDZØÒª±Èµ±Ç°¿ÉÓü¼Êõ¸ü¿ìµÄ»¥Á¬ £¬²¢ÇÒ±ØÒª»º´æÒ»ÖÂÐÔ £¬ÒÔ±ãÔÚÒì¹¹¶à´¦ÖÃÆ÷ϵͳÖиü¿ìµØ½Ó¼ûÄÚ´æ¡£CCIX¹æ·¶µÄ×î´óÓÅÊÆÊÇËü³ÉÁ¢ÔÚPCI Express¹æ·¶µÄ»ù´¡Ö®ÉÏ £¬µ«ËüÒò²»×ã¹Ø¼üÐÐÒµÖ§³Ö £¬´ÓÎ´ÕæÕýÌÚ·É¡£

¶øCXLÒÀ¸½ÏÖÓеÄPCIe5.0µÄÎïÀí²ãºÍµçÆø²ã³ß¶È¼°Éú̬ϵͳ £¬ÎªÄÚ´æ¼ÓÔØ/´æ´¢£¨load/Store)ÊÂÎñÔö³¤»º´æÒ»ÖÂÐԺ͵ÍʱÑÓ¸öÐÔ¡£ÓÉÓÚ³ÉÁ¢ÁËÐÐÒµÖдóÎÞÊýÖØÒª²Î¼ÓÕß¶¼Ö§³ÖµÄÐÐÒµ³ß¶ÈºÍ̸ £¬CXLʹÏòÒì¹¹ÍÆËãµÄ¹ý¶É³ÉΪ¿ÉÄܲ¢»ñµÃ¿í·ºµÄÒµ½çÖ§³Ö¡£AMDµÄGenoaºÍIntelµÄSapphireRapids½«ÔÚ2022Ëêĺ/2023ËêÊ×Ö§³ÖCXL1.1¡£ÖÁ´Ë £¬CXL³ÉΪҵ½çºÍѧÊõ½ç×îÓÐǰ;½â¾öÕâÒ»ÎÊÌâµÄ¼¼ÊõÖ®Ò»¡£

CXL¹¹½¨ÔÚPCIeÎïÀí²ãÉÏ £¬¾ß±¸ÏÖÓÐPCIeÎïÀí¼°µçÆø½Ó¿Ú¸öÐÔ £¬Ìṩ¸ß´ø¿í £¬¸ß¿ÉÀ©´óÐÔÌØµã¡£Áí±íCXLÓ봫ͳµÄPCIExpress£¨PCIe£©»¥Á¬Ïà±ÈÓµÓиüµÍµÄʱÑÓ £¬²¢ÇÒ»¹Ìṩһ×é¹ÖÒìµÄÐÂÖ°ÄÜʹCPU¿ÉÄÜÒÔÓµÓмÓÔØ/´æ´¢(load/store)ÓïÒåµÄ¸ßËÙ»º´æÒ»Ö£¨Cache-Coherent£©·½Ê½Óë±íΧÉ豸£¨ÄÚ´æÀ©´óºÍ¼Ó¿ìÆ÷¼°ÆäÏνӵĴ洢Æ÷£©Í¨Ñ¶¡£¸Ã¼¼Êõά³ÖCPUÄÚ´æ¿Õ¼äºÍ¸½¼ÓÉ豸ÉÏÄÚ´æµÄÒ»ÖÂÐÔ £¬ÔÊÐí×ÊÔ´¹²Ïí £¬´Ó¶ø»ñµÃ¸ü¸ß»úÄÜ £¬½µµÍÈí¼þÕ»¸´ÔÓÐÔ¡£ÓëÄÚ´æÓйصÄÉ豸À©´óÊÇCXLÖØÒªÖ¸±ê³¡¾°Ö®Ò»¡£

½ð²Ê»ã - Ê×Ò³

CXLÒÀ¸½ÏÖÓÐPCIeÎïÀí¼°µçÆø½Ó¿Ú¸öÐÔ

½ð²Ê»ã - Ê×Ò³

CXL/PCIeʵÏÖÄÚ´æ×ÊÔ´À©´ó/³Ø

CXL¼¼ÊõµÄµÀÀí

CXLÏÖʵÉÏÔ̺¬ÈýÖÖºÍ̸ £¬µ«²¢·ÇËùÓкÍ̸¶¼ÊÇÑÓ³¤µÄÁ鵤ÃîÒ©¡£CXL.io£¨ÔËÐÐÔÚPCIe×ÜÏßµÄÎïÀí²ãÉÏ£©ÒÀȻӵÓÐÓëÒÔÍùÒ»ÑùÀàÐ͵ÄÑÓ³¤ £¬µ«ÆäËûÁ½¸öºÍ̸ £¬CXL.cacheºÍCXL.memѡȡÁ˸ü¿ìµÄõè¾¶ £¬Ï÷¼õÁËÑÓ³¤¡£´óÎÞÊýCXLÄÚ´æ½ÚÔìÆ÷»áÔöԼĪ100-200ÄÉÃëµÄÑÓ³¤ £¬¶î±íµÄ³Á°´Ê±Æ÷»áÔö³¤»òÆÆ·Ñ¼¸Ê®ÄÉÃë £¬¾ßÌåÈ¡¾öÓÚÉ豸ÓëCPUµÄ¾àÀë¡£

½ð²Ê»ã - Ê×Ò³

CXLÒýÈëʱÑÓÓëNUMA¿¿½ü

½ð²Ê»ã - Ê×Ò³

CXL/PCIeÀ©´óÄÚ´æÏµÍ³¼Ü¹¹

CXLÔÚPCIePHY²ã¸´ÓÃ·ÖÆçµÄºÍ̸ £¬CXL1.0/1.1¹æ·¶¸½´ø3¸öºÍ̸֧³Ö-CXL.io¡¢CXL.cacheºÍCXL.mem £¬´óÎÞÊýCXLÉ豸½«Ê¹ÓÃCXL.io¡¢CXL.cacheºÍCXL.memµÄ×éºÏ¡£CXL.io ʹÓÃÓë PCIe Ò»ÑùµÄÊÂÎñ²ãÊý¾Ý°ü (Transaction Layer Packet, TLP)ºÍÊý¾ÝÁ´Â·²ãÊý¾Ý°ü (DLLP)¡£TLP/DLLP¸²¸ÇÔÚCXL flitµÄÓÐЧ¸ºÔز¿ÃÅÉÏ¡£CXL½ç˵ÁË¿ç·ÖÆçºÍ̸ջÌṩËùÐè·þÎñÖÊÁ¿(QoS)µÄÕ½Êõ¡£PHY¼¶´ËÍâºÍ̸¸´ÓÿÉÈ·±£CXL.cacheºÍCXL.memoryµÈÑÓ³¤Ãô¸ÐºÍ̸ӵÓÐÓë±¾»úCPUµ½CPU¶Ô³ÆÒ»ÖÂÐÔÁ´Â·Ò»ÑùµÄµÍÑÓ³¤¡£CXLΪÕâЩÑÓ³¤Ãô¸ÐºÍ̸½ç˵ÁËÒý½Åµ½Òý½ÅÏìÓ¦¹¦·òµÄÉÏÏÞ £¬ÒÔÈ·±£Æ½Ì¨»úÄܲ»»áÒòʵÏÖÒ»ÖÂÐÔºÍÄÚ´æÓïÒåµÄ·ÖÆçÉ豸֮¼äµÄÑÓ³¤²î¾à½Ï´ó¶øÊܵ½²»ÀûÓ°Ïì¡£


  • CXL.ioÄܹ»±»ÒÔΪÊdz߶ÈPCIeµÄÒ»¸öÀàËÆµ«¸Ä½øµÄ°æ±¾¡£

    ÊÇÓÃÓÚ³õʼ»¯¡¢Á´½Ó¡¢É豸·¢ÏÖºÍö¾ÙÒÔ¼°×¢²á½Ó¼ûµÄºÍ̸¡£ËüΪI/OÉ豸Ìṩ½Ó¿Ú £¬ÀàËÆÓÚPCIeGen5¡£CXLÉ豸Ҳ±ØÐëÖ§³ÖCXL.io¡£

  • CXL.cacheÊǽç˵Ö÷»ú£¨Í¨³£ÊÇCPU£©ºÍÉ豸£¨ÀýÈçCXLÄÚ´æÄ£¿é»ò¼Ó¿ìÆ÷£©Ö®¼ä½»»¥µÄºÍ̸¡£

ÓÉÓÚ°²È«Ê¹ÓÃÆä±¾µØ¸±±¾ £¬CXL.cacheÔÊÐíCXLÉ豸Á¬¹áµØ½Ó¼û»ººÍ´æÖ÷»úCPUµÄÄÚ´æ £¬Äܹ»°ÑÕâÉèÏë³ÉÒ»¸öGPUÖ±½Ó´ÓCPUµÄÄÚ´æÖлº´æÊý¾Ý¡£

  • CXL.memÊÇΪÖ÷»ú´¦ÖÃÆ÷£¨Í¨³£ÊÇCPU£©ÌṩʹÓüÓÔØ/´æ´¢ºÅÁîÖ±½Ó½Ó¼ûÉ豸¸½¼ÓÄÚ´æµÄºÍ̸¡£

ÔÊÐíÖ÷»úCPUÁ¬¹áµØ½Ó¼ûÉ豸µÄÄÚ´æ £¬½«´ËÊÓΪCPUʹÓÃרÓô洢¼¶ÄÚ´æÉ豸»òʹÓÃGPU/¼Ó¿ìÆ÷É豸ÉϵÄÄÚ´æ¡£

½ð²Ê»ã - Ê×Ò³

´Ó×óÏòÓÒ˳´ÎÊÇCXLType1¡¢CXLType3¡¢CXLType2

CXL 2.0Ôö³¤Á˶ÔÄÚ´æ³ØºÍCXL»¥»»µÄÖ§³Ö £¬ÔÊÐí¶à¶àÖ÷»úºÍÉ豸ȫÊýÁ´½Ó²¢Ï໥ͨѶ £¬´Ó¶øÊ¹ÏνÓÔÚCXLÍøÂçÉϵÄÉ豸ÊýÁ¿ÏÔ×ÅÔö³¤¡£¶ą̀Ö÷»úÄܹ»Ïνӵ½»¥»»»ú £¬¶øºó½«»¥»»»úÏνӵ½¸÷ÀàÉ豸 £¬ÈôÊǸÃCXLÉ豸ÊǶàÍ·µÄ²¢Ïνӵ½¶à¸öÖ÷»úµÄ¸ù¶Ë¿Ú £¬ÔòÒ²Äܹ»ÔÚûÓл¥»»»úµÄÇé¿öÏÂʵÏÖ¡£SLD£¨µ¥¸öÂß¼­É豸£©Êǵ¥¸öÖ÷»ú±ðÀëʹÓÃ·ÖÆçÄÚ´æ³Ø £¬MLD£¨¶à¸öÂß¼­É豸£©Ö¼ÔÚñîºÏ¶à¸öÖ÷»úÒÔ·ÖÏíͳһÎïÀíÄÚ´æ³Ø¡£

É¢²¼Ê½ÄÚ´æ×ÊÔ´ÍøÂ罫ÓɽṹÖÎÀíÆ÷£¨FabricManager£©ÕƹܷÖÅäÄÚ´æ¼°É豸±àÅÅ £¬ËüÏ൱ÓÚ½ÚÔìÆ½Ãæ»òЭµ÷Æ÷ £¬Î»ÓÚµ¥¶ÀµÄоƬÉÏ»ò»¥»»»úÖÐ £¬Í¨³£²»±ØÒª¸ß»úÄÜ £¬ÓÉÓÚ²»½Ó´¥Êý¾ÝÃæ¡£½á¹¹ÖÎÀíÆ÷£¨FabricManager£©ÌṩÓÃÓÚ½ÚÔìºÍÖÎÀí¸ÃϵͳµÄ³ß¶ÈAPI £¬Äܹ»ÊµÏÖϸÁ£¶ÈµÄ×ÊÔ´·ÖÅä¡¢ÈȲå°ÎºÍ¶¯Ì¬À©ÈÝÔÊÐíÓ²¼þÔÚ¸÷¸öÖ÷»úÖ®¼ä¶¯Ì¬·ÖÅäºÍ×ªÒÆ £¬ÎÞÐèÈκγÁÆô¡£½«ËùÓÐÕâЩ½áºÏÔÚһ· £¬Î¢Èí»ã±¨ÏÔʾѡȡCXL·½Ê½ÊµÏÖÄÚ´æ×ÊÔ´³ØÕûÌå¿ÉÏ÷¼õ10%ÄÚ´æÐèÒª £¬½ø¶ø½µµÍ5%µÄ×Ü·þÎñÆ÷³É±¾µÄDZÁ¦¡£

½ð²Ê»ã - Ê×Ò³

½ð²Ê»ã - Ê×Ò³

CXL 2.0ÄÚ´æ×ÊÔ´³Ø£¨Switch vs Directconnectģʽ£©

CXL¼¼ÊõµÄ·¢Õ¹

CXL·¢Õ¹ÊÆÍ·Ç¿¾¢ £¬ÈýÐÇ¡¢SKº£Á¦Ê¿¡¢Marvell¡¢Rambus¡¢ÈýÐÇ¡¢AMDµÈ´ó³§ÃǵIJ¼¾ÖÒ²ÔÚ²»Ðݼӿì¡£¹«ÓÐÔÆ¹©¸øÉÌÔÚÄÚµÄËùÓг¬´ó¹æÄ£ÆóÒµ¶¼ÆðÍ·³¢ÊÔÒÀÀµCXLÏνÓÄÚ´æ³ØÀ´¸ÄÉÆÄÚ´æÏÐÖà £¬¶¯Ì¬½Ã½ÝÔö³¤´ø¿íºÍÈÝÁ¿µÄÎÊÌâ¡£µ«µ±Ç°Ã»ÓÐÌ«¶àÓÃÓÚAPPʹÓñ¾µØ/±í²¿»ìºÏ»ïÔ´³ØµÄ¶à¼¶ÄÚ´æµ÷¶ÈÖÎÀí¼à¿Ø¼¼Êõ £¬Òò¶øÔÆ·þÎñÉÌÈôÊÇ¿ÌÒâ´ó¹æÄ£Ê¹ÓûùÓÚCXL¼¼ÊõµÄ×ÊÔ´³ØÏµÍ³ £¬ÒªÃ´×Ô¼º½¨ £¬ÒªÃ´µÃѰÕÒÏàÒ˵ÄϵͳÈíÓ²¼þ¹©¸øÉÌ¡£Õâ·½ÃæÎ¢Èí¡¢MetaµÈÖØÒªÔÆ·þÎñÉÌÒѾ­×ßµ½Ç°Ãæ¡£

΢ÈíµÄPond¹æ»®Ê¹Óûúе½ø½¨ÅжϷÖÎöÐé»úÊÇ·ñÊÇʱÑÓÃô¸ÐÒÔ¼°²»±»Ê¹ÓõĶuntouched£©ÄÚ´æ´óÓ× £¬²¢ÓÉ´ËÀ´Åжϵ÷¶ÈVMÔÚÏàÒ˵ı¾µØ»òCXLÔ¶¶ËÄÚ´æµØÎ» £¬¹²Í¬»úÄÜ¼à¿ØÏµÍ³²»Ðݵ÷ÕûǨáã¡£

½ð²Ê»ã - Ê×Ò³

 Î¢ÈíPond¹æ»®½ÚÔìÆ½Ãæ¹¤×÷Á÷³Ì

£¨A) µÄVM µ÷¶È·¨Ê½Ê¹ÓûùÓÚ ML µÄÔ¤²âÀ´¼ø±ðÑÓ³¤Ãô¸ÐµÄÐé¹¹»ú¼°Æä¿ÉÄÜδ´¥¼°µÄÄÚ´æÁ¿¾ö¶¨Ðé¹¹»úµÄ¸éÖÃ

£¨B) ¼à¿ØÈôÊÇ·þÎñÖÊÁ¿ (QoS) ²»Âú×ã £¬µ÷¶ÈǨáã½ÚÔìÖÎÀíÆ÷£¨Mitigation Manager£©»á³ÁÐÂÅäÖÃÐé¹¹»ú

×÷ΪÖÇËãÖÐÐÄÍøÂ罨ÉèÕß £¬½ð²Ê»ãÍøÂçÖÂÁ¦ÓÚΪ¿Í»§Ìṩ´´ÐµIJúÆ·¹æ»®ºÍ·þÎñ £¬Íƶ¯ÐÐÒµ·¢Õ¹ºÍ´´Ð £¬Èÿͻ§Ó뽫À´¸üçÇÃܵØÏνÓ¡£½ð²Ê»ãÍøÂ罫³ÖÐø´´Ð £¬ÒýÁìÖÇËãʱÆÚµÄÍøÂç·¢Õ¹³±Ë®¡£

²Î¿¼Îļþ£º

TPP: Transparent Page Placement for CXL-Enabled Tiered-Memory

Pond: CXL-Based Memory Pooling Systems for Cloud Platforms

Demystifying CXL Memory with Genuine CXL-Ready Systems and Devices

Compute Express Link™ Specification 3.0 whitepaper

Design and Analysis of CXL Performance Models for Tightly-Coupled Heterogeneous Computing

Memory Disaggregation: Advances and Open Challenges

Network Requirements for Resource Disaggregation

A Case for CXL-Centric Server Processors

¹Ø×¢½ð²Ê»ã
gfwx_logo
¹Ø×¢½ð²Ê»ã¹ÙÍøÎ¢ÐÅ
ËæÊ±Ïàʶ¹«Ë¾×îж¯Ì¬
½ð²Ê»ã - Ê×Ò³

·µ»Ø¶¥²¿

ÊÕÆð
½ð²Ê»ã - Ê×Ò³ ÎĵµAI¸±ÊÖ
½ð²Ê»ã - Ê×Ò³ ÎĵµÆÀ¼Û
ev-close ev-close-m
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close ev-close-m
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close ev-close-m
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
Ϊ¾¡¿ì½â¾öÎÊÌâ £¬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿