½ð²Ê»ã

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹â×êÑл㱨¡· £¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¢¼´ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
½ð²Ê»ã - Ê×Ò³
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
½ð²Ê»ã - Ê×Ò³
TS6800-20X4V2Q
TS6800-20X4V2Q
TS6800-20X4V2Q
TS6800-20X4V2Q
TS6800-20X4V2Q
TS6800-20X4V2Q
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

20¿ÚÍòÕ×£¨¼æÈÝ2.5G£©Èý²ãÖ÷Ìâ»ã¾ÛÍøÂ绥»»»ú £¬4¸ö25G¹â¿Ú£¨ÏòϼæÈÝ10G£© £¬40GÉÏÐÐ £¬TS6800-20X4V2Q

Ϊ´óÐÍÍøÂç»ã¾Û¡¢ÖÐÓ×ÐÍÍøÂçÖ÷Ìâ¡¢Ô°ÇøÊý¾ÝÖÐÐĽÓÈëÌṩÁ˸߻úÄÜ¡¢ÃÀÂúµÄ¶Ëµ½¶ËµÄ·þÎñÖÊÁ¿¡¢½Ã½Ý·á˶µÄ°²È«ÉèÖà £¬Âú×ã¸ßËÙ¡¢°²È«¡¢ÖÇÄܵįóÒµÍøÐèÒª¡£

²úÆ·¸öÐÔ£º

  • ¶Ë¿Ú·á˶ £¬20¸öÍòÕ×¹â¿Ú£¨ÏòϼæÈÝ2.5G£© £¬4¸ö25G¹â¿Ú £¬2¸ö40G¶Ë¿ÚÓÃÓÚÉÏÁª
  • Ö§³ÖVSUÐé¹¹»¯¼¼Êõ £¬½Ã½Ý×éÍø»úÄÜÇ¿
  • Ó²¼þ¼¶¶à³Á±£»¤ £¬±£ÏÕÉ豸³ÖÐøÔËÐÐ £¬ÍøÂç²»±ä²»µôÏß
  • ¶àÖÖÍøÂ簲ȫսÊõ £¬ÊµÊ±¼à²â £¬±£ÕÏÍøÂç³ÖÐø×³ÊµÐÔ
  • ÃÀÂúµÄQoSÕ½Êõ £¬ÊµÏÖÍøÂç×ÊÔ´½Ã½Ý·ÖÅä £¬ËٶȲ»±ä²»Óµ¼·
  • ¶à³ÁÍøÂçÖÎÀí·½Ê½ £¬ÊµÏÖµ¥Ò»ÇáËɵÄÍøÂçÊØ»¤
Á¢¼´Õ÷ѯ

²úÆ·¸ÅÊö

TS6800-20X4V2QÈÚºÏÁË·á˶µÄÔ°ÇøÓëÊý¾ÝÖÐÐĸöÐÔ £¬¸ÃϵÁл¥»»»úѡȡÏȽøµÄÓ²¼þ¼Ü¹¹Éè¼Æ £¬Ìṩ¸ü¿ìµÄÓ²¼þ´¦ÖûúÄÜ¡¢¸ü±ã½ÝµÄ²Ù×÷ʹÓÃÂÄÀú¡£

TS6800-20X4V2QÌṩ½Ã½ÝµÄÍòÕ׹⡢¶àËÙ¶È£¨10G/2.5G/1G£©½ÓÈëÄÜÁ¦ £¬Ö§³Ö¸ß»úÄÜ10G/40G¶Ë¿ÚÉÏÐÐÄÜÁ¦ £¬³ä·ÖÂú×ãÓû§¸ßÃܶȽÓÈëºÍ¸ß»úÄÜ»ã¾ÛµÄÐèÒª¡£

TS6800-20X4V2Q»¥»»»úΪ´óÐÍÍøÂç»ã¾Û¡¢ÖÐÓ×ÐÍÍøÂçÖ÷Ìâ¡¢Ô°ÇøÊý¾ÝÖÐÐĽÓÈëÌṩÁ˸߻úÄÜ¡¢ÃÀÂúµÄ¶Ëµ½¶ËµÄ·þÎñÖÊÁ¿¡¢½Ã½Ý·á˶µÄ°²È«ÉèÖà £¬Âú×ã¸ßËÙ¡¢°²È«¡¢ÖÇÄܵįóÒµÍøÐèÒª¡£

²úÆ·¸öÐÔ

IPv4/IPv6Ë«ºÍ̸ջ¶à²ã»¥»»

Ó²¼þÖ§³ÖIPv4/IPv6Ë«ºÍ̸ջ¶à²ãÏßËÙ»¥»» £¬Ó²¼þ·Ö±æºÍ´¦ÖÃIPv4¡¢IPv6ºÍ̸±¨ÎÄ £¬¿Éƾ¾ÝIPv6ÍøÂçµÄÐèÒª¹æ»®ÍøÂç»òÕßά³ÖÍøÂç½ü¿ö £¬Ìṩ½Ã½ÝµÄIPv6ÍøÂçͨѶ¹æ»®¡£Ö§³Ö·á˶µÄIPv4·ÓɺÍ̸ £¬Ô̺¬¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPFv2¡¢IS-ISv4¡¢BGP4µÈ £¬Âú×ã·ÖÆçÍøÂç»·¾³ÖÐÓû§Ñ¡ÔñÏàÒ˵Ä·ÓɺÍ̸½Ã½Ý×é½¨ÍøÂ硣ͬʱ֧³Ö·á˶µÄIPv6·ÓɺÍ̸ £¬Ô̺¬¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢IS-ISv6¡¢BGP4+µÈ £¬²»ÂÛÊÇÔÚÉý¼¶ÏÖÓÐÍøÂçÖÁIPv6ÍøÂç £¬»¹ÊÇн¨IPv6ÍøÂç £¬¶¼¿É½Ã½ÝÑ¡ÔñÏàÒ˵Ä·ÓɺÍ̸×é½¨ÍøÂç¡£

Ðé¹¹»¥»»µ¥Ôª£¨VSU £¬Virtual Switching Unit£©

Ö§³ÖÐé¹¹»¥»»µ¥Ôª¼¼Êõ£¨VSU £¬Virtual Switch Unit£©¼´Ðé¹¹»¥»»µ¥Ôª¼¼Êõ¡£Í¨¹ý¾ÛºÏÁ´Â·µÄÏνÓ £¬¿ÉÄܽ«¶ą̀ÎïÀíÉ豸½øÐл¥Áª £¬Ê¹ÆäÐ鹹Ϊһ̨Âß¼­É豸 £¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet¹ý³Ì¡¢µ¥Ò»ºÅÁîÐнӿڡ¢×Ô¶¯°æ±¾²é³­¡¢×Ô¶¯ÅäÖõȸöÐÔ½øÐÐÖÎÀí £¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚÖÎÀíһ̨É豸 £¬µ«ÊÇȴʵÏÖ×Ŷą̀É豸´øÀ´µÄ¹¤×÷ЧÄܺÍʹÓÃÂÄÀú¡£

¼ò»¯ÖÎÀí£ºÖÎÀíÔ±Äܹ»¶Ô¶ą̀»¥»»»úͳһÖÎÀí £¬¶ø²»±ØÒªÏνӵ½Ã¿Ì¨»¥»»»ú±ðÀë½øÐÐÅäÖúÍÖÎÀí¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨»¥»»»ú £¬Í¨¹ý¾ÛºÏÁ´Â·ºÍ±íΧÉ豸ÏνÓ £¬²»´æÔÚ¶þ²ã»·Â· £¬Ã»±ØÒªÅäÖÃMSTPºÍ̸ £¬¸÷Àà½ÚÔìºÍ̸ÊÇ×÷Ϊһ̨»¥»»»úÔËÐеÄ¡£

ºÁÃë¼¶¹ÊÕϸ´Ô­£ºVSUºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓ £¬ÈôÊÇÆäÖÐһ̨É豸»òÕßÒ»Ìõ³ÉÔ±Á´Â·³öÏÖ¹ÊÕÏ £¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄ×î¶Ì¹¦·ò²»¸ßÓÚ30ºÁÃë¡£

¸ßÀ©´óÐÔ£ºÓû§ÐÂÔöµÄÉ豸²ÎÓë»òÍÑÀëÐé¹¹»¯ÍøÂçʱÄܹ»ÊµÏÖ¡°ÈȲå°Î¡± £¬²»Ó°ÏìÆäËûÉ豸µÄÕý³£ÔËÐС£

ÃÀÂúµÄ°²È«·À»¤Õ½Êõ

ÓµÓеĶàÖÖÄÚº­»úÔìÄܹ»ÓÐЧ·À±¸ºÍ½ÚÔ첡¶¾´«²¼ºÍºÚ¿Í¹¥»÷ £¬ÈçÔ¤·ÀDoS¹¥»÷¡¢·ÀºÚ¿ÍIPɨÃè»úÔì¡¢¶Ë¿ÚARP±¨ÎĵĺϷ¨ÐԲ鳭¡¢¶àÖÖÓ²¼þACLÕ½ÊõµÈ £¬»¹ÍøÂçһƬÂÌÉ«¡£

Ö§³Ö»ùÓÚÓ²¼þµÄIPv6 ACL £¬¼´±ãÔÚIPv4ÍøÂçÄÚÓÐIPv6Óû§ £¬Ò²¿ÉÇáËÉÔÚÍøÂç±ßԵʵÏÖ¶ÔIPv6Óû§µÄ½Ó¼û½ÚÔì £¬¼È¿ÉÔÊÐíÍøÂçÄÚIPv4/IPv6Óû§²¢´æ £¬Ò²Äܹ»¶ÔIPv6Óû§µÄ½Ó¼ûȨÏÞ½øÐнÚÔì £¬ºÃ±ÈÏ޶ȶÔÍøÂçÃô¸Ð×ÊÔ´µÄ½Ó¼ûµÈ¡£

Ó²¼þCPU±£»¤»úÔì£ºÌØÉ«µÄCPU±£»¤Õ½Êõ £¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷ £¬½øÐÐÁ÷·Ö±æºÍÓÅÏȼ¶¶ÓÁзּ¶´¦Öà £¬²¢Æ¾¾Ý±ØÒªÖ´Ðдø¿íÏÞËÙ £¬³ä·Ö±£»¤CPU²»±»·¸·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´¿÷Ë𠣬±£ÏÕÁËCPU°²È« £¬³ä·Ö±£»¤ÁË»¥»»»úµÄ°²È«¡£

Ó²¼þʵÏֶ˿ڻò»¥»»»úÕû»úÓëÓû§IPµØÖ·ºÍMACµØÖ·µÄ½Ã½Ý°ó¶¨ £¬ÑϸñÏÞÔì¶Ë¿ÚÉϵÄÓû§½ÓÈë»ò»¥»»»úÕû»úÉϵÄÓû§½ÓÈëÎÊÌâ¡£

Ö§³ÖDHCP Snooping £¬¿ÉÖ»ÔÊÐíÐÅÀµ¶Ë¿ÚµÄDHCPÏìÓ¦ £¬Ô¤·À˽ÉèDHCP ServerµÄºýŪ£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ £¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ²é³­Óû§µÄIP £¬Ö±½ÓÅׯú²»Çкϰ󶨱íÏîµÄ·¸·¨±¨ÎÄ £¬ÓÐЧ·À±¸ARPºýŪºÍÓû§Ô´IPµØÖ·µÄºýŪÎÊÌâ¡£

»ùÓÚÔ´IPµØÖ·½ÚÔìµÄTelnetÉ豸½Ó¼û½ÚÔì £¬Ô¤·À·¸·¨ÈËÔ±ºÍºÚ¿Í¶ñÒâ¹¥»÷ºÍ½ÚÔìÉ豸 £¬¼ÓÇ¿ÁËÉè±¸Íø¹ÜµÄ°²È«ÐÔ¡£

SSH£¨Secure Shell£©ºÍSNMPv3Äܹ»Í¨¹ýÔÚTelnetºÍSNMP¹ý³ÌÖмÓÃÜÖÎÀíÐÅÏ¢ £¬±£ÕÏÖÎÀíÉ豸ÐÅÏ¢µÄ°²È«ÐÔ £¬Ô¤·ÀºÚ¿Í¹¥»÷ºÍ½ÚÔìÉ豸¡£

½ÚÔì·¸·¨Óû§Ê¹ÓÃÍøÂç £¬±£ÕϺϷ¨Óû§ºÏÀí»¯Ê¹ÓÃÍøÂç £¬Èç¶àÔªËØ°ó¶¨¡¢¶Ë¿Ú°²È«¡¢¹¦·òACL¡¢»ùÓÚÊý¾ÝÁ÷µÄ´ø¿íÏÞËÙµÈ £¬Âú×ãÆóÒµÍø¡¢Ð£Ô°Íø¼ÓÇ¿¶Ô½Ó¼ûÕß½øÐнÚÔì¡¢ÏÞ¶È·ÇÊÚȨÓû§Í¨Ñ¶µÄÐèÒª¡£

Ö§³Ö»ù´¡ÍøÂç±£»¤Õ½Êõ£¨NFPP £¬Network Foundation Protection Policy£© £¬ÓÃÀ´¼ÓÇ¿»¥»»»ú°²È«µÄÒ»ÖÖ±£»¤ÏµÍ³ £¬Í¨¹ý¶Ô¹¥»÷Ô´Í·²ÉÈ¡¸ôÀë´ëÊ© £¬Äܹ»Ê¹»¥»»»úµÄ´¦ÖÃÆ÷ºÍÐÅ·´ø¿í×ÊÔ´µÃµ½±£»¤ £¬´Ó¶ø±£Õϱ¨ÎĵÄÕý³£×ª·¢ÒÔ¼°ºÍ̸״̬µÄÕý³£¡£

¸ß¿¿µÃסÐÔ

Ö§³ÖÄÚÖÃÈßÓàµçÔ´Ä£¿éºÍÄ£¿é»¯µçÉÈ×é¼þ £¬µçÔ´Ä£¿éÒÔ¼°µçÉÈÄ£¿é¾ùÄܹ»ÈȲå°Î¶ø²»Ó°ÏìÉ豸µÄÕý³£ÔËÐС£´Ë±íÕû»ú»¹Ö§³ÖµçÔ´ºÍµçÉȵĹÊÕϼì²â¼°¸æ¾¯ £¬Äܹ»Æ¾¾Ýζȵı䶯×Ô¶¯µ÷½ÚµçÉȵÄתËÙ £¬¸üºÃµÄÊÊÓ¦»·¾³¡£É豸֧³Öǰ/ºó͸·ç £¬ÌáÉýÉ¢ÈÈЧÄÜ £¬»¹¾ß±¸É豸¼¶ºÍÁ´Â·¼¶µÄ¶à³Á¿¿µÃסÐÔ±£»¤¡£Ñ¡È¡¹ýÁ÷±£»¤¡¢¹ýѹ±£»¤ºÍ¹ýÈȱ£»¤¼¼Êõ¡£

Ö§³ÖÌìÉúÊ÷ºÍ̸802.1D¡¢802.1w¡¢802.1s £¬ÆëÈ«±£Õϼ±¾çÊÕÁ² £¬Ìá¸ßÈÝ´íÄÜÁ¦ £¬±£ÕÏÍøÂçµÄ²»±äÔËÐкÍÁ´Â·µÄ¸ºÔØÆ½ºâ £¬ºÏÀíʹÓÃÍøÂçͨ· £¬ÌṩÈßÓàÁ´Â·ÀûÓÃÂÊ¡£

Ö§³ÖÐ鹹·ÓÉÆ÷ÈßÓàºÍ̸£¨VRRP£© £¬ÓÐЧ±£ÏÕÍøÂç²»±ä¡£

Ö§³Ö¼±¾çÁ´Â·¼ì²âºÍ̸£¨RLDP £¬Rapid Link Detection Protocol£© £¬¿É¼±¾ç¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ £¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²âÖ°ÄÜ £¬Ô¤·À¶Ë¿ÚÏÂÒò˽½ÓHubµÈÉ豸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵľ°Ïó¡£

ÔÚ²»ÆôÓÃSTPµÄÇé¿öÏ £¬Äܹ»Í¨¹ý¼±¾çÉÏÁ´±£»¤ºÍ̸£¨REUP £¬Rapid Ethernet Uplink Protection Protocol£© £¬Ìṩһ¸ö¼±¾çÉÏÁ´±£»¤Ö°ÄÜ £¬REUPʹµÃÓû§ÔڹعØSTPµÄÇé¿öÏ £¬ÈÔÌṩ¸ù»ùµÄÁ´Â·ÈßÓà £¬Í¬Ê±Ìṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϸ´Ô­¡£

Ö§³ÖBFD £¬Îª¸÷ÉϲãºÍ̸Èç·ÓɺÍ̸ÌṩһÖÖ¼±¾ç¼ì²âÁ½Ì¨Â·ÓÉÉ豸֮¼äת·¢õè¾¶Á¬Í¨×´Ì¬µÄ²½Öè £¬´ó´óÏ÷¼õÁËÉϲãºÍ̸ÔÚÁ´Â·×´Ì¬±ä¶¯Ê±µÄÊÕÁ²¹¦·ò¡£

׳´óµÄ¶àÒµÎñÖ§³ÖÄÜÁ¦

Ö§³ÖIPv4¡¢IPv6×é²¥Ö°ÄÜ £¬Ô̺¬·á˶µÄ×é²¥ºÍ̸¡£ºÃ±ÈIGMP Snooping¡¢IGMP¡¢MLD¡¢PIM¡¢PIM for IPv6¡¢MSDPµÈºÍ̸×å £¬ÎªIPv4ÍøÂç¡¢IPv6ÍøÂç¡¢IPv4ºÍIPv6¹²´æµÄÍøÂçÌṩÁË×é²¥·þÎñÖ§³Ö¡£

Ö§³ÖIGMPÔ´¶Ë¿ÚºÍÔ´IP²é³­Ö°ÄÜ £¬ÓÐЧµØ¶Å¾ø·¸·¨µÄ×é²¥Ô´ £¬Ìá¸ßÍøÂçµÄ°²È«ÐÔ¡£

ÃÀÂúµÄQoSÕ½Êõ

¾ß±¸MACÁ÷¡¢IPÁ÷¡¢ÀûÓÃÁ÷µÈ¶à²ãÁ÷·ÖÀàºÍÁ÷½ÚÔìÄÜÁ¦ £¬ÊµÏÖ¾«ÃܵÄÁ÷´ø¿í½ÚÔ졢ת·¢ÓÅÏȼ¶µÈ¶àÖÖÁ÷Õ½Êõ £¬Ö§³ÖÍøÂçÆ¾¾Ý·ÖÆçµÄÀûÓá¢ÒÔ¼°·ÖÆçÀûÓÃËù±ØÒªµÄ·þÎñÖÊÁ¿¸öÐÔ £¬Ìṩ·þÎñ¡£

ÒÔDiffServ³ß¶ÈΪÖ÷ÌâµÄQoS±£ÏÕϵͳ £¬Ö§³Ö802.1P¡¢IP ToS¡¢¶þµ½Æß²ãÁ÷¹ýÂË¡¢SP¡¢WRRµÈÆëÈ«µÄQoSÕ½Êõ £¬ÊµÏÖ»ùÓÚÈ«ÍøÏµÍ³¶àÒµÎñµÄQoSÂß¼­¡£

ÂÌÉ«½ÚÄÜ

TS6800-20X4V2Q»¥»»»úѡȡÁËÐÂÒ»´úµÄÓ²¼þ¼Ü¹¹ÒÔ¼°ÏȽøµÄ½ÚÄܵç·Éè¼ÆºÍÔªÆ÷¼þÑ¡ÐÍ £¬ÎªÓû§½Ú¼óÄܺÄ £¬Í¬Ê±½µµÍÔëÒô´«È¾¡£È«ÏµÁвúÆ·¾ùѡȡÖáÁ÷±äËÙµçÉÈÉè¼Æ £¬É豸¿Éƾ¾Ýµ±Ç°µÄζÈÖÇÄܽÚÔìµçÉÈתËÙ £¬±£ÏÕÉ豸²»±ä¹¤×÷µÄͬʱ £¬½µµÍ¹¦ºÄºÍÔëÉù¡£

µ¥Ò»ÇáËɵÄÍøÂçÊØ»¤

Ö§³ÖSNMP¡¢RMON¡¢Syslog¡¢USB±¸·ÝÈÕÖ¾¼°ÅäÖõȸöÐÔÀ´½øÐÐÍøÂçµÄÈÕ³£Õï¶Ï¼°ÊØ»¤ £¬Í¬Ê±ÖÎÀíÔ±¿ÉѡȡºÅÁîÐнӿÚ(CLI)¡¢WebÍø¹Ü¡¢TelnetµÈ¶àÑù»¯µÄÖÎÀíºÍÊØ»¤·½Ê½¸ü·½±ãÉ豸µÄÖÎÀí¡£

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

Ö÷»ú

Ó²¼þ¹æ¸ñ TS6800-20X4V2Q
½Ó¿Ú¹æ¸ñ
¹Ì»¯ÒµÎñ½Ó¿Ú 20¸ö1G/2.5G / 10G SFP+¹â¿Ú£»
4¸ö10G / 25G SFP28¹â¿Ú£»2¸ö40G QSFP+¹â¿Ú£»
Õû»ú×î´ó¿ÉÖ§³Ö32¸ö10G¶Ë¿Ú
Ä£¿é²å²Û 2¸öÄ£¿é»¯µçÔ´²å²Û
2¸öÄ£¿é»¯µçÉȲå²Û
¹Ì»¯ÖÎÀí½Ó¿Ú 1¸öMGMT¶Ë¿Ú
1¸öConsole ¶Ë¿Ú
1¸öUSB¶Ë¿Ú
µçÔ´Ó빦ºÄ
µäÐ͹¦ºÄ 85W(Âú¸ººÉ)
¶î¶¨ÊäÈëµçѹ RG-PA150IB-F£º
  • »¥»»£¨AC£©ÊäÈ룺

¶î¶¨µçѹ£º100-240VAC;
ƵÂÊ£º50/60Hz
¶î¶¨ÊäÈëµçÁ÷£º3A
  • ¸ßѹµçÁ÷£¨HVDC£©ÊäÈ룺

¶î¶¨µçѹ£º240VDC
¶î¶¨ÊäÈëµçÁ÷£º3A
×î´óÊäÈëµçѹ RG-PA150IB-F£º£º
  • »¥»»£¨AC£©ÊäÈ룺

×î´óµçѹ£º90-264VAC
ƵÂÊ£º47/63Hz
¶î¶¨ÊäÈëµçÁ÷£º3A
  • ¸ßѹµçÁ÷£¨HVDC£©ÊäÈ룺

×î´óµçѹ£º192-288VDC
ÿ·¶î¶¨ÊäÈëµçÁ÷£º3A
µçÉÈÀàÐÍ Ö§³Ö¿É°Î²å˫ģ¿é»¯µçÉÈ £¬Ç°ºó·ç·
Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯ְÄÜ
³ß´çÓë³ÁÁ¿
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 440.0mm x 330.0mm x 43.6mm
²úÆ·³ÁÁ¿ 4.6kg£¨º¬Á½¸öµçÉÈ £¬²»º¬¿ª¹ØµçÔ´£©
»·¾³Óë¿¿µÃסÐÔ
µçÔ´½Ó¿Ú·ÀÀ× 6KV
ÎÂ¶È¼à¿Ø Ö§³Öζȸ澯
¹¤×÷ÎÂ¶È 0¡æ~50¡æ
´æ´¢ÎÂ¶È -40¡æ~70¡æ
¹¤×÷ʪ¶È 10%RH~90%RH
´æ´¢Êª¶È 5%RH~95%RH

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ TS6800-20X4V2Q
VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖGVRP
Ö§³ÖSuper VLAN
QinQ Ö§³Ö¸ù»ùQinQ¡¢Ö§³Ö½Ã½ÝQinQ
Á´Â·¾ÛºÏ Ö§³ÖLACP(802.3ad)
¶Ë¿Ú¾µÏñ Ö§³Ö»ùÓÚÁ÷µÄ¾µÏñ
Ö§³Ö¶à¶ÔÒ»¶Ë¿Ú¾µÏñ¼°Ò»¶Ô¶à¶Ë¿Ú¾µÏñ
Ö§³ÖRSPAN
Ö§³Ö¾ÛºÏÁ´Â·µÄ¾µÏñ
ÌìÉúÊ÷ Ö§³ÖSTP¡¢RSTP¡¢MSTP
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
IPv6»ù´¡ºÍ̸ IPv6±àÖ·¡¢ICMPv6¡¢Path MTU Discovery
IP·ÓÉ Ö§³Ö¾²Ì¬Â·ÓÉ
Ö§³ÖRIP £¬RIPng
Ö§³ÖOSPFv2 £¬OSPFv3 £¬IS-ISv4 £¬IS-ISv6
Ö§³ÖBGP4 £¬BGP4+
Ö§³ÖµÈ¼Û·ÓÉ
×é²¥ Ö§³ÖIGMP v1 £¬v2 £¬v3 £¬IGMP´úÀí
Ö§³ÖIGMP v1 £¬v2ºÍv3 Snooping
Ö§³ÖIGMP ¹ýÂË £¬IGMP¼±¾çÍÑÀë
Ö§³ÖPIM-DM £¬PIM-SM £¬PIM-SSM
Ö§³ÖMLD Snooping £¬MLD
Ö§³ÖMSDP
ACL Ö§³Ö½Ã½Ý¶àÑùµÄÓ²¼þACL£º
Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë±êÓï¡¢ºÍ̸ÀàÐÍ¡¢¹¦·òµÈ½Ã½Ý×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/ToSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È
°²È«¸öÐÔ ¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
ÖÎÀí¸öÐÔ SNMP¡¢CLI(Telnet/Console)¡¢RMON(1,2,3,9)¡¢Syslog¡¢NTP¡¢SNMP over IPv6¡¢IPv6 MIB support for SNMP ¡¢Telnet v6¡¢FTP/TFTP v6¡¢DNS v6¡¢NTP for v6¡¢Traceroute v6
Ö§³ÖsFLOW £¬¿ÉÀûÓÃÊý¾ÝÁ÷Ëæ»ú²ÉÑù¼¼Êõ £¬¶Ô»¥»»»úµÄÁ÷Á¿½øÐÐÁ÷ÐÅÏ¢²ÉÑù
¸ß¿¿µÃסÐÔ Ö§³ÖVSU£¨Ðé¹¹»¯¼¼Êõ £¬½«¶ą̀É豸Ðé×é³É1̨£©¡¢Ö§³ÖGR for RIP/OSPF/BGPµÈ·ÓɺÍ̸¡¢Ö§³ÖBFD¼ì²â¡¢Ö§³ÖREUP¡¢Ö§³ÖRLDP¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢µçÔ´Ä£¿é¡¢µçÉÈÄ£¿éÖ§³ÖÈȲå°ÎÖ°ÄÜ
·¢Õ¹¾ßÌå²ÎÊý

³£¼ûÎÊÌâ

faq-none
ÔÝÎÞÎÊÌâ £¬ÎÒÒªÌáÎÊ
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgÁ¢¼´Õ÷ѯ
½ð²Ê»ã - Ê×Ò³

·µ»Ø¶¥²¿

ÊÕÆð
½ð²Ê»ã - Ê×Ò³ ÎĵµAI¸±ÊÖ
½ð²Ê»ã - Ê×Ò³ ÎĵµÆÀ¼Û
ev-close ev-close-m
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close ev-close-m
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close ev-close-m
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
Ϊ¾¡¿ì½â¾öÎÊÌâ £¬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
½ð²Ê»ã - Ê×Ò³
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿